{"id":14,"date":"2026-01-16T20:48:03","date_gmt":"2026-01-16T11:48:03","guid":{"rendered":"https:\/\/urabanashi.net\/?p=14"},"modified":"2026-04-18T00:46:10","modified_gmt":"2026-04-17T15:46:10","slug":"%e3%82%a6%e3%82%a8%e3%83%8f%e3%82%ab%e3%82%bb%e3%83%83%e3%83%88%e3%81%ae%e3%83%88%e3%83%ac%e3%83%bc%e3%82%b5%e3%83%93%e3%83%aa%e3%83%86%e3%82%a3%e7%ae%a1%e7%90%86","status":"publish","type":"post","link":"https:\/\/sigmax-ltd.com\/en\/%e3%82%a6%e3%82%a8%e3%83%8f%e3%82%ab%e3%82%bb%e3%83%83%e3%83%88%e3%81%ae%e3%83%88%e3%83%ac%e3%83%bc%e3%82%b5%e3%83%93%e3%83%aa%e3%83%86%e3%82%a3%e7%ae%a1%e7%90%86\/","title":{"rendered":"Traceability Management of Wafer Carriers"},"content":{"rendered":"<!-- main image -->\n    <!-- main image -->\n    <figure class=\"hero-media\">\n      <img decoding=\"async\" src=\"https:\/\/sigmax-ltd.com\/official\/wp-content\/uploads\/2026\/04\/main_TFxcasset_EN_1600x850.jpg\" alt=\"\">\n    <\/figure>\n<\/section>\n\n\n<section class=\"spec\">\n  <div class=\"spec-table\">\n<div class=\"row\">\n<div class=\"th\">\u3010Case Study Title\u3011 <\/div>\n<div class=\"td\">Traceability Management of Wafer Carriers<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"th\">\u3010Application \/ Installation\u3011<\/div>\n<div class=\"td\">Applied to the side surface of wafer carriers\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"th\">\u3010Product\u3011<\/div>\n<div class=\"td\">CERALABEL TF<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"th\">\u3010Challenges\u3011<\/div>\n<div class=\"td\">In semiconductor manufacturing processes, individual identification and tracking of silicon wafers are critical. As a result, proper management of wafer carriers is essential.\nHowever, in environments involving aggressive chemicals such as hydrofluoric acid (HF) cleaning, conventional labels often fail under such conditions, resulting in loss of readability.\n\n\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"th\">\u3010Solution \/ Benefits\u3011<\/div>\n<div class=\"td\">CERALABEL TF, a resin-molded barcode label with excellent resistance to hydrofluoric acid, was adopted.\nIt protects the printed surface even in harsh chemical environments, enabling long-term and stable identification.<br>\n\u25ce Stable readability even after hydrofluoric acid (HF) cleaning processes<br>\n\u25ce Reduced frequency of label replacement<br>\n\u25ce Improved reliability in quality control<br>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"th\">\u3010Mounting Options\u3011<\/div>\n<div class=\"td\">This product supports the following mounting methods depending on the application and operating environment:<br>\n\n1.A recessed area is machined on the cassette surface with appropriate clearance for the label. After insertion, the gap is filled with resin.<br>\n2.Mechanically fixed using resin bolts through pre-drilled holes in the cassette<br>\n3.Inserted into pre-machined slits on the cassette<br>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"\u3010\u30b1\u30fc\u30b9\u540d\u3011 \u30a6\u30a8\u30cf\u30ab\u30bb\u30c3\u30c8\u306e\u30c8\u30ec\u30fc\u30b5\u30d3\u30ea\u30c6\u30a3\u7ba1\u7406 \u3010\u53d6\u308a\u4ed8\u3051\u5148\u3011 \u30a6\u30a8\u30cf\u30ab\u30bb\u30c3\u30c8\u5074\u9762 \u3010\u88fd\u54c1\u3011 \u30bb\u30e9\u30e9\u30d9\u30ebT [&hellip;]","protected":false},"author":1,"featured_media":500,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[58],"tags":[],"class_list":["post-14","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-58"],"_links":{"self":[{"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/posts\/14","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/comments?post=14"}],"version-history":[{"count":4,"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/posts\/14\/revisions"}],"predecessor-version":[{"id":508,"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/posts\/14\/revisions\/508"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/media\/500"}],"wp:attachment":[{"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/media?parent=14"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/categories?post=14"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sigmax-ltd.com\/en\/wp-json\/wp\/v2\/tags?post=14"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}